Gas turbine gensets
performance data in ISO conditions


 

 

 

 

 

 

Gas turbines:

engines

gensets

mobile plants

turbocompressors

Diesel gensets

Dual-fuel and gas recip gensets

Steam turbines

 

Home

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

open cycle

 

 

cogeneration

 

combined cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open cycle

 

Parameter

PS2.5

PS6

PS15

PS15(STIG)

PS16

PS25

Rated output, kW

2 600

6 150

16 900

25 000

15800

26000

Electric efficiency,%

26.7

29.9

33.9

42.0

30.1

35.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Cogeneration

Parameter

PS2.5T

PS6T

PS10T

PS15T

PS25W

Electric output, MW

2.5

6.0

10.0

16.0

25.0

Open-cycle efficiency, %

26.0

30.1

34.2

32.8

34.8

Steam rate, tonne/hr

6.9

10.6

16.4

24.9

39.1

Steam pressure, psig

128

227

253

281

308

Steam temperature, oC

210

356

335

365

401

Total thermal output, MW

4.9

8.4

14.1

20.3

32.6

Overall thermal efficiency, %

78.6

74.6

82.4

76.9

81.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combined cycle

Parameter

Aquarius-9

Aquarius-16

Aquarius-25

Aquarius-40

Net plant output, kW

8 000

15 500

24 300

40 100

Gas turbine MCR, kW

6 300

10 780

17 500

26 700

Open-cycle efficiency, %

30.0

36.0

35.0

36.6

Net plant efficiency, %

36.3

42.5

41.5

42.5

Heat rate, Btu/kWh

9 000

8 050

8 240

7 860

Steam mass flow, kg/s

 

5.4

8.1

12.9

Pressure ratio

 

19.5

17.9

19.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


More information:


Tel: +64 9 575 3739, Fax: +64 9 575
3742